SOLAR • BATTERY SIZING
Solar Battery Calculator — Capacity, Backup Time & kWh
Page information: Author: Abdul Qadir · Updated: November 20, 2026
Methodology: Calculations are based on the formulas and assumptions explained on this page. See Calcora's calculation methodology.
Important: Results are estimates for planning and educational use. Check applicable official, professional, technical or regulatory guidance when a decision requires current or site-specific information.
Estimate battery energy and approximate amp-hour capacity for a defined backup load. Then understand the assumptions, chemistry, inverter, temperature and real-world checks that can change the final battery choice.
Formula, example and guide
Formula
Battery capacity is estimated from the required energy, system voltage and usable depth of discharge. Allow for inverter and other system losses rather than treating the calculated number as an exact battery specification.
Worked example
If a load needs 3 kWh of usable energy and the battery bank is 48 V, the required amp-hours depend on the usable fraction and conversion losses you enter. Use the result as a planning estimate and check the battery manufacturer limits.
How to use this calculator
Enter your expected load, backup time and battery assumptions. Review the result against the actual battery chemistry, inverter efficiency and backup conditions before buying equipment.
Calculate battery capacity
1. Why this number is calculated
Delivered energy = load (kW) × backup hours. Nominal battery energy is estimated as delivered energy ÷ [usable depth of discharge × efficiency]. Approximate Ah equals nominal battery watt-hours ÷ battery voltage.
Example: 1,000 W for 4 hours needs 4.00 kWh delivered. At 80% usable discharge and 90% efficiency, the planning estimate is about 5.56 kWh nominal storage, or about 116 Ah at 48 V.
2. Assumptions
- Backup load: assumes the stated load represents the average power that must be supported.
- Backup hours: defines how long the selected loads must run.
- Depth of discharge: represents the portion of nominal storage you plan to use.
- Efficiency: is a simplified planning allowance for conversion losses.
- Voltage: converts energy to approximate Ah; it does not prove electrical compatibility.
DC current is a separate battery limit
Battery energy in kWh describes how much energy can be stored; discharge current in amps describes how quickly the battery must deliver it. For a simplified steady load, DC current is approximately AC load watts ÷ (battery voltage × assumed battery/inverter efficiency). The actual current changes as battery voltage changes and can rise sharply during motor starts. Check the battery or BMS continuous and peak discharge-current limits, plus the inverter's DC input requirements; do not select a battery from Ah alone.
3. Lithium vs lead-acid
Battery chemistry affects usable capacity, discharge behavior, temperature sensitivity, maintenance, charging limits and aging. Two batteries with the same nominal Ah can therefore behave differently in a real installation.
Use the manufacturer's usable-energy and discharge specifications for final selection. Do not assume one universal depth-of-discharge value works for every battery.
4. Motors and starting surge
Refrigerators, pumps, fans, compressors and other motors can have higher starting demand than their running wattage. This calculator estimates energy; the inverter and battery must also support the required continuous and peak power.
5. Temperature and aging
Battery performance can change with temperature, age, charge state and discharge rate. A headline capacity should not be treated as guaranteed usable energy under every operating condition.
6. When does a solar battery make sense?
Not always. A battery is most useful when you need backup during outages, want stored solar energy after sunset, or have a system strategy that benefits from higher self-consumption. A grid-connected daytime-use system can have a different battery requirement from an off-grid or backup-focused system. For US homes, compare the value of backup and shifted energy with your utility rate plan and export-credit rules; this calculator does not estimate bill savings or payback.
7. Battery and inverter checks
- Confirm battery voltage compatibility.
- Check continuous and peak discharge current.
- Check supported battery chemistry and manufacturer requirements.
- Confirm charging limits and expected recharge time.
- Check inverter backup-load and surge limits.
- Allow for temperature, aging and future load changes.
8. What should you calculate next?
- Use the Solar Load Calculator to identify essential loads.
- Use the Solar Panel Calculator to estimate PV generation.
- Use this calculator to estimate backup storage.
- Review the Solar Inverter Guide before selecting equipment.
- Visit the Solar Calculator Hub for the complete workflow.
Example: how long will a 5 kWh battery run your appliances?
A battery's advertised kWh is its nominal stored energy, not necessarily the energy available to your appliances. For a transparent illustration, assume a 5.00 kWh nominal battery, 80% usable depth of discharge and 90% battery/inverter efficiency. Estimated delivered energy is 5.00 × 0.80 × 0.90 = 3.60 kWh.
| Constant AC load | Estimated backup time |
|---|---|
| 500 W | 7.2 hours |
| 1,000 W | 3.6 hours |
| 1,500 W | 2.4 hours |
| 2,000 W | 1.8 hours |
Formula: backup time (hours) = nominal battery kWh × usable discharge fraction × efficiency ÷ average AC load (kW). This example assumes a steady load and does not include inverter idle consumption, battery aging, temperature effects, changing load, low-voltage cut-off or surge demand. Real backup time can be lower; confirm usable energy and continuous/peak discharge limits in the battery and inverter datasheets.
Common mistakes
- Sizing for the whole house when only selected loads need backup.
- Using Ah without checking voltage and usable energy.
- Ignoring motor starting demand.
- Assuming all advertised capacity is always usable.
- Ignoring temperature and aging.
- Choosing a battery before checking inverter compatibility.
FAQ
How long will a 5 kWh battery run a 1 kW load?
With an illustrative 5.00 kWh nominal battery, 80% usable depth of discharge and 90% battery/inverter efficiency, delivered energy is 5.00 × 0.80 × 0.90 = 3.60 kWh. A constant 1 kW load would therefore run for about 3.6 hours. Actual runtime depends on usable battery energy, load variation, inverter consumption, temperature, aging, cut-off settings and discharge-current limits.
Can I use this for lithium batteries?
Yes, for first-pass planning. Follow the manufacturer's usable-energy, current, temperature and BMS requirements for final selection.
What about lead-acid?
Use manufacturer discharge limits and performance data because practical capacity depends on the application and discharge rate.
Does a larger battery always mean better backup?
No. The battery must be matched with the inverter, charging source, loads and required backup strategy.
Read the Solar Battery Guide · US Home Solar Load Guide · Panel Calculator · Load Calculator · Solar Calculator Hub