SOLAR • INVERTER SIZING • PAKISTAN
Solar Inverter Sizing Guide: How to Choose kW or kVA
A good inverter choice starts with the loads you actually need to run, then checks surge, PV, battery and electrical limits. Panel wattage alone is not enough.
1. Why the inverter number is calculated this way
Add the appliances expected to operate at the same time. Divide total running watts by 1,000 to get first-pass running kW. Then check motor or compressor startup demand and the inverter's continuous and peak ratings.
2. Assumptions
- Running wattage represents simultaneous normal demand.
- Motor and compressor loads may require higher startup power.
- PV generation is variable, so rated panel output is not a constant AC supply.
- Final installation must follow the exact inverter and appliance manufacturer limits.
3. Worked example
If essential loads total 3,200 W, first-pass running demand is 3.2 kW. If a pump or compressor starts during that period, check its startup requirement against the inverter's surge capability. Do not select the final model from 3.2 kW alone.
4. 3 kW, 5 kW and 10 kW planning
These are power classes, not automatic recommendations. A 3 kW inverter can suit a defined essential-load circuit, while 5 kW or 10 kW may suit higher simultaneous demand. Always verify the exact model's continuous, peak, PV and battery limits.
5. kW vs kVA
kW is real power; kVA is apparent power. When power factor is below 1, they differ. Use the appliance and inverter specifications rather than a universal conversion.
6. PV input and MPPT checks
- Maximum permitted PV power
- Maximum PV input voltage
- Maximum input current
- MPPT operating voltage range
- Number of MPPT trackers
- Permitted string configuration
Compare the panel voltage and current with these limits. String voltage must remain within the inverter's permitted range under relevant operating conditions.
7. Battery and backup checks
For hybrid or backup systems, check battery voltage range, charge/discharge current, supported chemistry, backup output and surge capability. Battery energy affects runtime; inverter power affects which loads can run together.
8. Pakistan solar planning
Separate daytime solar use from outage requirements. Fans, lights, refrigerators, pumps and air conditioners have different running and starting characteristics. Also consider temperature, shading, dust, wiring and the intended grid configuration when reviewing expected performance.
9. Common mistakes
- Choosing only from panel wattage.
- Ignoring startup surge.
- Ignoring PV voltage/current or MPPT limits.
- Confusing kW and kVA.
- Assuming a 5 kW panel array automatically requires a 5 kW AC inverter.
- Ignoring battery current and backup limits.
- Sizing the whole house when only essential loads need backup.
10. What should you calculate next?
- Use the Solar Load Calculator for demand.
- Use the Solar Panel Calculator for PV capacity.
- Use the Solar Battery Calculator for backup storage.
- Use the Solar Calculator Hub for the complete workflow.
FAQ
How many watts should my inverter be?
Start with maximum simultaneous running load, then verify surge and manufacturer limits.
Is a 5 kW inverter enough for a 5 kW solar system?
Not automatically. Check the inverter's permitted PV input and the complete system design.
Should I size for the whole house?
Only if the design requires the whole house simultaneously. For backup, define essential loads first.